Fire-resistance rating : ウィキペディア英語版
Fire-resistance rating

A fire-resistance rating typically means the duration for which a passive fire protection system can withstand a standard fire resistance test. This can be quantified simply as a measure of time, or it may entail a host of other criteria, involving other evidence of functionality or fitness for purpose.
==Common rating systems==
The following depict the most commonly used international time/temperature curves:

File:Din iso astm ul curves.JPG|Time/Temperature Curves used for testing the fire-resistance rating of passive fire protection systems such as firestops, fire doors, wall and floor assemblies, etc., which are used in compartmentalisation in buildings and the petrochemical industry in Europe and North America.
File:Tunnel_hc_iso_curves.jpg|Time/Temperature Curves used for testing the fire-resistance rating of passive fire protection systems in tunnels in Germany, The Netherlands and France.
File:Rws_tunnel_curve.jpg|Time/Temperature Curve used for testing the fire-resistance rating of passive fire protection system|systems in tunnels in The Netherlands.
File:Eurocode_1_curve.jpg|Time/Temperature Curve used for testing the fire-resistance rating of passive fire protection systems in Europe.
File:French hc curve 1.jpg|Time/Temperature Curve used for testing the fire-resistance rating of passive fire protection systems in tunnels in France.
File:German_tunnel_curves.jpg|Time/Temperature Curve used for testing the fire-resistance rating of passive fire protection systems in tunnels in Germany.
File:Euro_furnace_pressure.jpg|Furnace pressure is also subject to standardised tolerances for testing to obtain fire-resistance ratings. This image shows European tolerances, subject to NEN-EN 1363-1.
File:temp_tolerance.jpg|Furnace Temperatures for fire testing to obtain fire-resistance ratings are subject to certain tolerances. This graph shows the tolerance applicable to the European building elements / cellulosic curve.